3 人看过
A flange is not a flange. Three standards cover most of the industrial world, they look similar at a glance, and they do not bolt together. Choosing the wrong one is a mistake you discover at the hydrotest, when the gasket will not seat, the bolt holes are half a hole out of register, or the studs are the wrong diameter.
The three families
| Standard | Region and role | Pressure designation | Common sizes | Notes |
|---|---|---|---|---|
| ASME B16.5 | Global default for smaller flanges | Class 150, 300, 400, 600, 900, 1500, 2500 | 1/2 in to 24 in (NPS) | The reference point for most project piping classes |
| ASME B16.47 | Large diameter flanges | Same class series | 26 in to 60 in | Two series (A and B) with different bolt circles - they are not interchangeable |
| EN 1092-1 | European system | PN 6, 10, 16, 25, 40, 63, 100, 160, 250, 320, 400 | DN 10 to DN 4000 | Type-coded (Type 01, 11, 05, etc.) by facing and construction |
There is also JIS B2220 (5K to 30K), used in Japan and in plants built to Japanese specifications, and API 6A for wellhead equipment with its own numbering. Mixing any of these with an ASME class flange is a workshop job, not a field fix.
The four things that actually differ
Bolt circle and bolt count. This is the failure that stops a shutdown. A DN 100 PN 16 flange and a 4 in Class 150 flange are close in size and are not the same bolt pattern.
Bolt diameter. Class 150 through 600 use relatively small studs on a larger circle; Class 900 and above step up sharply. A 3/4 in Class 900 flange takes a meaningfully bigger stud than a Class 300 of the same size.
Facing. Raised face (RF) is the default. Ring type joint (RTJ) is standard for high pressure and for hydrogen and other services where a metal-to-metal seal is required. Flat face (FF) mates with cast iron or with equipment that must not be stressed. A raised face bolted to a flat face is a leak waiting for a warm-up.
Pressure-temperature derating. ASME class and EN PN numbers are not interchangeable at temperature. Every flange has a pressure-temperature curve in its own standard, and the curves are different shapes.
Where the projects get it wrong
| Situation | Typical error | Consequence |
|---|---|---|
| European-designed package, Middle East site | Package arrives PN 16, site piping is Class 150 | Bolt patterns differ; adaptor spools needed |
| Large bore line | B16.47 Series A specified, Series B delivered | Bolt circles do not match; entire spool rejected |
| Hydrogen or high-pressure gas | RF facing used where the spec required RTJ | Seal does not meet the leak class required |
| Valve with a mating flange in a different material group | Gasket type chosen by habit | Creep and relaxation; bolts lose preload |
The rule that prevents most of it
Specify the flange by standard, class, facing, size and material - all five - and put the mating flange in the same line of the requisition. "6 in Class 300 RF" is not a complete description; "6 in, ASME B16.5, Class 300, RF, ASTM A105, mating to B16.5 Class 300 RF" is.
For anything unusual - hydrogen, sour service, cryogenic, large bore - add the gasket type and the bolt material to the same line. The cost of those words is zero; the cost of a mismatch is measured in days of shutdown.
Check the face-to-face as well
Flange standard and valve face-to-face dimension are separate documents. Valve face-to-face is set by ASME B16.10 for ASME-class valves, and by the relevant EN standard (EN 558 is common) for the European series. A valve can have the right flange and the wrong face-to-face for the space it must fit - which is the second most common dimensional surprise in valve procurement.
Related reading
See our notes on pressure class and temperature derating, and on valve ordering codes, where the end-connection position is the one most often mistyped.
Need a quotation or technical clarification?
Request a quotation